FPI Recycle Startup - Service Mode
This procedure guides authorized personnel through starting the FPI Recycle system in service mode. Follow the approved startup sequence and applicable safety requirements, verify system responses, and record any abnormalities.
FPI Recycle Startup - Service Mode
The aim of this procedure is to standardize the startup of the FPI Recycle system in service mode, supporting controlled operation during authorized servicing and functional checks. It helps verify system readiness, identify faults early, and document issues requiring attention before further operation.
Are feed valves FV#1 and FV#2 are open?
if the answer is "oneOf [No]"
Are there any leaks or damage?
Is area clean and free of debris?
Permate Discharge Valve is open
if the answer is "oneOf [No]"
Is the tank level on polytank below red line (less than 1/4 full)?
if the answer is "oneOf [Yes]"
With pump#1 (service mode) on, is the pressure gauge PG#1 between 180-210 psi?
if the answer is "oneOf [No]"
With pump#1 on, is the flow rate on rotameters within 0.13gpm and 0.5gpm?
if the answer is "oneOf [No]"
Is the rotameter RM#3 flowrate within 3gpm and 4gpm?
if the answer is "oneOf [No]"