Atosa Ice Maker Cleaning and Sanitizing Procedure (Type: YR280-AP-161)
The Atosa Ice Maker Cleaning and Sanitizing procedure ensures the ice machine remains hygienic and operates efficiently. This involves turning off the machine, removing ice, cleaning internal components to remove scale and buildup, and sanitizing all food-contact surfaces according to manufacturer guidelines before restarting the unit.
Atosa Ice Maker Cleaning and Sanitizing Procedure (Type: YR280-AP-161)
The Atosa Ice Maker Cleaning and Sanitizing procedure ensures the ice machine remains hygienic and operates efficiently. This involves turning off the machine, removing ice, cleaning internal components to remove scale and buildup, and sanitizing all food-contact surfaces according to manufacturer guidelines before restarting the unit.
Clean and Sanitize
CLEANING/SANITIZING PROCEDURE GENERALITIES
This procedure must be performed a minimum of once every three months.
EXTERIOR CLEANING
Clean the area around the ice machine as often as necessary to maintain cleanliness and efficient operation. Wipe surfaces with a damp cloth rinsed in water to remove dust and dirt from the outside of the ice machine. If a greasy residue persists, use a damp cloth rinsed in a mild dish soap and water solution. Wipe dry with a clean, soft cloth. The exterior panels have a clear coating that is stain resistant and easy to clean. Products containing abrasives will damage the coating and scratch the panels.
Cleaning / Sanitizing Procedure
Health and Safety
• Warning: Wear rubber gloves and safety goggles (and/or face shield) when handling Ice Machine Cleaner or Sanitizer. • Caution: Do not mix Cleaner and Sanitizer solutions together. It is a violation of Federal law to use these solutions in a manner inconsistent with their labeling • Caution: Never use anything to force ice from the evaporator. Damage may result
Cleaning Procedure Steps
Ice machine cleaner is used to remove lime scale and mineral deposits. Ice machine sanitizer disinfects and removes algae and slime. the cleaner and sanitizer we use are: 1) 0OF-ATIMD01 ATOSA POWDER DESCALER 48/CASE 2) 0OF-ATIMD02 ATOSA POWDER RINSE 48/CASE
SANITIZING PROCEDURE
Parts Removal for Cleaning/Sanitizing
For Model YR140-AP-161, YR280-AP-161
Condenser air-filter wash
Water filter and air filter
Water Filter
The Cartridge must be changed each 06 months 0OF-ATIMD02 ATOSA POWDER RINSE 48/CASE
Air Filter
Clean air-filter once a month
Source: ABIC (Community Member)