(M) Antares - Inspect Jib Crane (OLD)

This procedure walks through a full inspection of the Antares jib crane to confirm it's safe and ready for continued use.
Helion Energy Facilities
09/23/2026

(M) Antares - Inspect Jib Crane (OLD)

This preventive maintenance task ensures the jib crane remains safe, compliant, and operational through a monthly frequent inspection in accordance with ASME B30.11 §11-2.1.2 and aligned with WAC 296-24. Work includes verification of controls and emergency stop, inspection of hooks, wire rope or load chain, hoist operation, trolley movement, structural components, and safety devices. Routine inspection helps identify wear or deficiencies early, maintaining safe and reliable lifting operations.

    Purpose

    Identify wear, damage, maladjustment, or functional deficiencies before they create unsafe lifting conditions or equipment failure.

    Scope

    Applies to functional and condition-based inspection of the jib crane structure, hoist assembly, trolley system, hook and latch assembly, wire rope or load chain, limit devices, external electrical controls, and visible mounting components in accordance with ASME B30.11 §11-2.1.2 (Frequent Inspection – Normal Service). Includes verification of operating controls and emergency stop, hoist brake function, upper limit device operation, condition of hooks and latches, inspection of wire rope or load chain, trolley travel components, structural members, mounting hardware, and capacity markings to ensure safe and compliant operation. This monthly inspection does not include internal disassembly or measurement-based structural evaluation, which is performed under the Annual Periodic Inspection per ASME B30.11 §11-2.1.3. Safety Notes: ☐ Notify affected personnel prior to inspection ☐ Barricade work area if required ☐ Ensure crane is not under load before beginning work ☐ Do not inspect under a suspended load ☐ Follow lockout/tagout (LOTO) procedures if accessing electrical components ☐ Use proper fall protection if working at elevation ☐ Wear required PPE (gloves, safety glasses, hard hat as required) Recommended Personnel: ☐ Facilities maintenance technician (designated person per ASME B30.11) Estimated Time: ☐ 1 hour per crane

    Tools/Parts

    Required Tools:

    Required Parts:

    Optional:

    Procedure

    1. Preparation

    2. Controls & Emergency Stop (ASME B30.11 §11-2.1.2 – Operating Mechanisms)

    3. Hoist Operation & Brake (ASME B30.11 §11-2.1.2 – Hoist Mechanisms)

    5. Hook Assembly (ASME B30.11 §11-2.1.2 – Hooks)

    6. Wire Rope / Load Chain (ASME B30.11 §11-2.1.2 – Rope/Chain Condition)

    7. Trolley & Travel Components (ASME B30.11 §11-2.1.2 – Moving Parts)

    8. Structural Components (ASME B30.11 §11-2.1.2 – Structural Items)

    9. Electrical Components (External)

    10. Labels & Markings

    Deficiency Criteria

    (Reference: ASME B30.11 §11-2.4 – Maintenance & Removal from Service) If any of the following are observed: • Structural cracks • Damaged hook or missing latch • Wire rope damage beyond visual acceptance • Brake malfunction or load drift • Non-functional limit switch • Loose structural mounting → Remove crane from service immediately → Tag Out of Service → Generate corrective work order (if needed) → Notify Facilities Maintenance Lead and Operations Manager

    Are there any visible structural cracks on the jib arm, mast, or mounting components?

    • Pass
    • Flag
    • Fail

    Is the hook free of damage and equipped with a functioning safety latch?

    • Pass
    • Flag
    • Fail

    Is the wire rope or load chain free of damage beyond acceptable visual limits (e.g., no severe wear, kinks, broken wires, or deformation)?

    • Pass
    • Flag
    • Fail

    Is the hoist brake functioning properly with no load drift?

    • Pass
    • Flag
    • Fail

    Is the upper limit switch fully functional and stopping upward travel as intended?

    • Pass
    • Flag
    • Fail

    Is the crane securely mounted with no loose structural hardware or mounting components?

    • Pass
    • Flag
    • Fail

    Completion

    Click here to sign
Source: Helion Energy Facilities (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.