Extol - Monthly Preventive Maintenance
This procedure involves verifying the functionality of safety equipment, cleaning various components, performing necessary maintenance actions, and ensuring proper documentation and review. It is designed to ensure the Extol Infrastake Welder is operating safely and efficiently.
Extol - Monthly Preventive Maintenance
This procedure involves verifying the functionality of safety equipment, cleaning various components, performing necessary maintenance actions, and ensuring proper documentation and review. It is designed to ensure the Extol Infrastake Welder is operating safely and efficiently.
Verification of Safety Equipment
Verify all E-stops are working properly
If no, perform lockout/tagout and contact automation/maintenance. Must be repaired before continuing.
Check if all safety equipment is in working order
Includes switches, light curtains, etc.
Look for any visual signs of damage to equipment
Cleaning Procedures
Wear cotton gloves and clean the inside surface of the concentrators and reflectors
Restore the most reflective surface possible with a microfiber towel. Refer to laminated instructions in the program book Extol manual page 17.
Clean frame, fixtures, and inside of cell
Use scrubbing bubbles and microfiber towels.
Clean sensors using microfiber towels
Clean fixture and cell
Maintenance Actions
Manually drain the filter/regulator unit of all debris and fluid
Is corrective action needed?
If yes, write in comments below.
Documentation and Review
Verify that there is a log sheet and equipment operation standard on the cell
Does this PM need to be updated?
If yes, write in comments below.
Comments
Parts used
Technician Name
Source: MTNA-G (Community Member)