This procedure is used to inspect and service positive displacement pumps so wear, damage, and buildup are found before they cause a pump failure.
Goodland Crush - Scoular
03/19/2026

Positive Displacement Pumps (PD Pump) Inspection

This procedure outlines the inspection of positive displacement (PD) pumps to keep them operating reliably. After notifying operations and applying lockout/tagout, it guides the technician through inspecting the couplings, guards, mounting fasteners, shaft play, gearbox oil, shaft seal, pump head internals (bull gear, idler gear, check valve), motor conduit, motor buildup, and cooling fan, followed by cleanup and sign-off.

    Some pumps may have only one coupling. Others may have two.

    Remove coupling and inspect components of coupling

    Falk grid couplings - should have two halves of grid and no wear on grid or hub wear grid rides. Omega Couplings - Any dry rot, cracking, or rubber peeling from metal will require replacement

    • Pass
    • Flag
    • Fail

    Ensure hubs are tight to shaft and keyways are not loose.

    • Pass
    • Flag
    • Fail

    Is guarding OK?

    • Pass
    • Flag
    • Fail

    Check all mounting fasteners on pump, motor, and gearbox if applicable

    • Pass
    • Flag
    • Fail

    Inspect Motor, gearbox, and pump for shaft play.

    • Pass
    • Flag
    • Fail

    ISO 220 Oil

    Seal OK on pump shaft?

    • Pass
    • Flag
    • Fail

    TAKE NOTE OF ORIENTATION OF CHECK VALVE PRIOR TO REMOVAL

    Inspect bull gear for wear. OK?

    • Pass
    • Flag
    • Fail

    Inspect idle gear for wear? OK?

    Both the gear side and play on shaft need inspected.

    • Pass
    • Flag
    • Fail

    Inspect inside of check valve for build ups and blockage. remove if present

    • Pass
    • Flag
    • Fail

    Inspect flex conduit going to motor is it OK?

    • Pass
    • Flag
    • Fail

    Inspect motor for build up. Remove any build up

    • Pass
    • Flag
    • Fail

    Cooling fan OK?

    • Pass
    • Flag
    • Fail

    Sign after completion of work

    Click here to sign
Source: Goodland Crush - Scoular (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.