Back

Weekly Lift Mechanical Inspection – RLX

This procedure outlines the weekly mechanical inspection of the RLX lift system, including terminals, drive components, brakes, grips, carriers, tension systems, and auxiliary power units. It helps verify safe, reliable operation by identifying abnormal wear, misalignment, leaks, or safety hazards before they impact riders, employees, or lift performance.
Crested Butte - Lift Maintenance
11/25/2025

Weekly Lift Mechanical Inspection – RLX

This procedure outlines the weekly mechanical inspection of the RLX lift system, including terminals, drive components, brakes, grips, carriers, tension systems, and auxiliary power units. It helps verify safe, reliable operation by identifying abnormal wear, misalignment, leaks, or safety hazards before they impact riders, employees, or lift performance.

    Drive Terminal Inspections

    Service brake inspection

    Inspect braking surface and pads

    • Pass
    • Flag
    • Fail

    Bullwheel brakes inspection

    Inspect braking surface and pads

    • Pass
    • Flag
    • Fail

    Gearbox inspection

    Visually inspect Gearbox. Check for leaks and housing discoloration

    • Pass
    • Flag
    • Fail

    Overall cleanliness of terminal

    • Pass
    • Flag
    • Fail

    APU and EPU Startup

    Run APU uncoupled for 10 minutes per ANSI weekly startup requirement

    10 minutes may be cumulative over the entire week (a few minutes each day is preferred)

    Enter APU/EPU Fuel Level

    Meter name
    Unit

    Hour Meter reading for APU

    Meter name
    Unit

    Run EPU uncoupled for 10 minutes per ANSI weekly startup requirement

    10 minutes may be cumulative over the entire week (a few minutes each day is preferred)

    Hour Meter reading for EPU

    Meter name
    Unit

    Grips, Carriers, Line

    Return Terminal inspection

    Tension system inspection

    • Pass
    • Flag
    • Fail

    Overall cleanliness of terminal

    • Pass
    • Flag
    • Fail

    Final Inspection

    Final Inspection Procedure - All

    Notes:

    Are all stations free of any employee or guest safety hazards?

    • Yes
    • No
    • N / A

    Record asset hour meter reading

    Lift hour meter reading should be selected for most situations. If work is performed on an engine or generator, please select the hour meter reading for auxiliary power unit, evacuation power unit, or generator. If you have questions regarding which hour meter reading to select, please contact your supervisor.

    Meter name
    Unit
    if the answer is "> 0 "

    Hour Meter Reading

    Verify that you have selected the correct meter, and that the hour meter reading is the current value.

    • Pass
    • Flag
    • Fail
Source: Crested Butte - Lift Maintenance (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.