Jensen L-Tron DTX Dryer Annual PM
Regular maintenance significantly reduces fire risk, extends the dryer's lifespan, improves energy efficiency, and ensures optimal drying performance
Jensen L-Tron DTX Dryer Annual PM
Regular maintenance significantly reduces fire risk, extends the dryer's lifespan, improves energy efficiency, and ensures optimal drying performance
*** LOTO Confirmation Statement - DO NOT EDIT/REMOVE ***
All hazardous energy has been isolated using LOTO procedures?
All potential stored or residual energy has been relieved, disconnected, restrained, lowered, and/or otherwise rendered safe?
Lock Out Tag Out
LOTO Performed
Food Safety Pre-Check
ENERGY CONTROL PROGRAM
Utilize the Cintas ENERGY CONTROL PROGRAM Checklist when applying LOTO.
Annual Burner Inspection
Complete burner inspection and safety checks
Verify burner firing rate
Perform gas valve leakage test
Check gas train filter and replace if necessary
Inspect burner and diffuser plate integrity
Check diffuser plate and wings for chipping, cracking and debris build-up
Orifices/ports should be uniform and clean of debris
Check Electrical Connections
Check all electrical connections to ensure all wires are firmly seated and terminal screws are tight.
Moisture Inhibitor
Replace the moiture inhibitor inside the cabinet with new.
Clean Up
Clean up all tools, parts, and debris from the work area.
Repair made or needed:
Food Safety Post-Check
Source: 24P DC Columbus - Cintas (Community Member)