Look over the overall appearance of the machine.
Inspect the condition of the nip and dancer rollers.
Drain the air tank and regulators filters
Inspect the air lines for any leaks or pinch markings.
Inspect the condition and tension of timing belts
Inspect the Teflon and heater heads for damage.
Inspect the wire cables to each of the heads for exposed wire or fraying.
Check for bearing wear and metal debris on or around rollers.
Grease all grease points around the machine.
Look for any water leaks on and around the machine.
Verify that all the estops and light curtains are working properly.
Verify that all the temperature controllers are working and displaying correct temperature.
Change all air media filters on the electrical junction boxes.
Remove cover and apply light coat of food grade grease to feedscrew on the unwinders.
Inspection observation of machine.
Tools cleared
Cleaned, Cleared for Production.