A structured audit of the Tomra system to evaluate sorting accuracy, sensor performance, mechanical condition, and software functionality, ensuring the equipment operates within established specifications and all findings are documented to support continuous improvement and regulatory compliance.
Gabbs - Premier Magnesia
03/20/2025

Tomra Audit

This procedure ensures that the Tomra system undergoes a thorough audit covering sorting accuracy, sensor calibration, mechanical condition, software performance, and overall system compliance, verifying that the equipment is operating within established specifications, identifying any deviations or deficiencies requiring corrective action, and supporting consistent product quality and regulatory compliance throughout all associated sorting and processing operations.
Procedure Max Score: 300

    Auditor Names:

    Responsible Manager/Supervisor for Follow-up:

    Operator Controls

    Is the White board being updated and hazards being tracked?

    • Pass
    • Flag
    • Fail

    Are the operators filling out their AIS's or work permits correctly?

    • Pass
    • Flag
    • Fail

    Permit to Work: Are permits to work properly completed and implemented?

    • Pass
    • Flag
    • Fail

    Hot Work: Are hot work permits properly completed and implemented?

    • Pass
    • Flag
    • Fail

    Are operators wearing the correct PPE for their area?

    • Pass
    • Flag
    • Fail

    Have the operators been tasked trained and have a 5000-23 for the equipment they use?

    • Pass
    • Flag
    • Fail

    Does the operator have a way to communicate hazards? (e.g. radio, hand held radio)

    • Pass
    • Flag
    • Fail

    Are first aid cabinets being properly stocked

    • Pass
    • Flag
    • Fail

    Do the personnel in the area understand their role in an emergency involving fire?

    • Pass
    • Flag
    • Fail

    Are all fire extinguishers' monthly inspections current and initialed?

    • Pass
    • Flag
    • Fail

    Are fire extinguishers mounted correctly

    • Pass
    • Flag
    • Fail

    Are energy sources controlled from loss (air leaks, natural gas, burners operating without need)?

    • Pass
    • Flag
    • Fail

    Are eyewash and shower stations adequate and expiration tags legible?

    • Pass
    • Flag
    • Fail

    Roadways & Berms

    Are all roadways clear of debris?

    • Pass
    • Flag
    • Fail

    Are all required traffic signs and traffic markers clearly visible and in place?

    • Pass
    • Flag
    • Fail

    Are berms at an adiquite height for the equipment working in the area?

    • Pass
    • Flag
    • Fail

    Are lighting levels adequate?

    • Pass
    • Flag
    • Fail

    Are barricades and warning signs in place in all required areas requiring restricted access?

    • Pass
    • Flag
    • Fail

    Are signs posted for any area where an entire building or area within the plant is "off limits"?

    • Pass
    • Flag
    • Fail

    Are all required traffic signs and traffic markers clearly visible and in place?

    • Pass
    • Flag
    • Fail

    Mobile Equipment

    Are the operators doing and filling out the Pre-Op inspections correctly?

    • Pass
    • Flag
    • Fail

    Is the area free of debris such as rags, cans, hoses, tools, etc.?

    • Pass
    • Flag
    • Fail

    Are all pre-operation inspections being completed on each shift prior to equipment being used?

    • Pass
    • Flag
    • Fail

    Are the vehicle's brakes set and wheels chocked?

    • Pass
    • Flag
    • Fail

    Is the cab/bed/tool boxes of the vehicle clean and free of trash,and parts, tools organized?

    • Pass
    • Flag
    • Fail

    Is there any accumulation of flammable materials?

    • Pass
    • Flag
    • Fail

    Are all fire extinguishers' monthly inspections current and initialed?

    • Pass
    • Flag
    • Fail

    Are fire extinguishers mounted correctly

    • Pass
    • Flag
    • Fail

    Are seatbelts in good condition with no fraying?

    • Pass
    • Flag
    • Fail

    Do seatbelts latch correctly?

    • Pass
    • Flag
    • Fail

    Are all windows & mirrors clean and adjusted correctly for the operator?

    • Pass
    • Flag
    • Fail

    Do all lights work correctly?

    • Pass
    • Flag
    • Fail

    Does the backup alarm/horn work correctly and is loud enough for the surrounding noises?

    • Pass
    • Flag
    • Fail

    Housekeeping & Storage

    Is the area free of debris such as rags, cans, hoses, tools, etc.?

    • Pass
    • Flag
    • Fail

    Are floors clean and clear of build-up?

    • Pass
    • Flag
    • Fail

    Are designated storage areas clearly marked?

    • Pass
    • Flag
    • Fail

    Is the area free of parts and materials, or are they stored properly?

    • Pass
    • Flag
    • Fail

    Are hoses rolled up and slings and ladders stored properly?

    • Pass
    • Flag
    • Fail

    Are trash can/dumpster lids in place and being closed?

    • Pass
    • Flag
    • Fail

    Are designated walkways kept clear of debris and equipment?

    • Pass
    • Flag
    • Fail

    Are designated storage areas clearly marked?

    • Pass
    • Flag
    • Fail

    Is the support structure adequate for the material being stored?

    • Pass
    • Flag
    • Fail

    Are all walkways and aisles in storage areas clearly marked by 4-inch safety yellow border?

    • Pass
    • Flag
    • Fail

    Are storage racks loaded beyond design capacity?

    • Pass
    • Flag
    • Fail

    Are hazardous materials stored in approved containers and cabinets properly labeled?

    • Pass
    • Flag
    • Fail

    Are tools, equipment, and materials stacked/stored on top of lockers?

    • Pass
    • Flag
    • Fail

    Are flame cabinets kept clean and no combustibles stored in/on them?

    • Pass
    • Flag
    • Fail

    Are cylinders stored adequate distances from heat sources?

    • Pass
    • Flag
    • Fail

    Are oxygen cylinders stored a minimum of 20 feet away from flammable gas cylinders?

    • Pass
    • Flag
    • Fail

    Are the gauges on the regulators legible and in good working order?

    • Pass
    • Flag
    • Fail

    Does each cylinder have a current inspection tag or stamp?

    • Pass
    • Flag
    • Fail

    Is there signage for cylinders in area?

    • Pass
    • Flag
    • Fail

    Are heaters positioned at least 10 feet away from combustible materials?

    • Pass
    • Flag
    • Fail

    Are flammable material stored around heaters?

    • Pass
    • Flag
    • Fail

    Are restrooms cleaned and stocked with supplies?

    • Pass
    • Flag
    • Fail

    Are all signs clean and legible?

    • Pass
    • Flag
    • Fail

    Do signs provide adequate information for hazards present?

    • Pass
    • Flag
    • Fail

    Conveyor Belts and Screws

    Are there holes in the belting?

    • Pass
    • Flag
    • Fail

    Are the belts running true or do they need to be tracked?

    • Pass
    • Flag
    • Fail

    Is the skirting for the belt in good repair and keeping the materal on the belt?

    • Pass
    • Flag
    • Fail

    Are return rollers guarded along walkways or places under seven feet from working surfaces?

    • Pass
    • Flag
    • Fail

    Are there hand rails or e-stops along the belts?

    • Pass
    • Flag
    • Fail

    Is there a chain/belt guard to keep from whipping off at head/tail pulley?

    • Pass
    • Flag
    • Fail

    Are trough rollers in good repair?

    • Pass
    • Flag
    • Fail

    Is there material building up under the belts keeping rollers from operating correctly?

    • Pass
    • Flag
    • Fail

    Safety

    Are designated walkways kept clear of debris and equipment?

    • Pass
    • Flag
    • Fail

    Are floor areas below electrical panels and safety equipment kept clear for ready access?

    • Pass
    • Flag
    • Fail

    Are walkways and stairways free of equipment, parts, tools, and debris?

    • Pass
    • Flag
    • Fail

    Are adequate handrails, midrails, and toe boards installed on elevated walkways and platforms?

    • Pass
    • Flag
    • Fail

    Are all straight run fixed ladders less than 30 feet in length?

    • Pass
    • Flag
    • Fail

    Are all fixed ladders at least 75 degrees and no more than 90 degrees from horizontal?

    • Pass
    • Flag
    • Fail

    Have fixed ladder been compermised by being bent or damaged?

    • Pass
    • Flag
    • Fail

    Are there handrails on all stairways and are they in good repair?

    • Pass
    • Flag
    • Fail

    Are ladders free of oil, grease, and other slipping hazards?

    • Pass
    • Flag
    • Fail

    Are areas adjacent to top and bottom of ladders free of debris, material, and obstructions?

    • Pass
    • Flag
    • Fail

    Are portable ladders in good repair with stickers readable and intack?

    • Pass
    • Flag
    • Fail

    Do fixed ladders project at least 42 inches above landings?

    • Pass
    • Flag
    • Fail

    Are portable ladders stored on suitable racks?

    • Pass
    • Flag
    • Fail

    Do portable ladders have slip-resistant bases?

    • Pass
    • Flag
    • Fail

    Are all portable ladders made of fiberglass?

    • Pass
    • Flag
    • Fail

    Are machinery guards painted yellow?

    • Pass
    • Flag
    • Fail

    Is equipment identified with numbers and, where necessary, with descriptions?

    • Pass
    • Flag
    • Fail

    Piping: Does pipe label clearly indicate contents of line, direction, and hazard?

    • Pass
    • Flag
    • Fail

    Piping: Are pipe lines marked frequently enough?

    • Pass
    • Flag
    • Fail

    Are lighting levels adequate?

    • Pass
    • Flag
    • Fail

    Are all lighting fixtures secure and lenses and/or bulbs clear of dust and debris and guarded to prevent shock or burn to employees?

    • Pass
    • Flag
    • Fail

    Permit to Work: Are permits to work properly completed and implemented?

    • Pass
    • Flag
    • Fail

    Hot Work: Are hot work permits properly completed and implemented?

    • Pass
    • Flag
    • Fail

    Are all areas where health or safety hazards exist clearly marked?

    • Pass
    • Flag
    • Fail

    Are warning signs readily visible, legible, and display the hazard & protective action required?

    • Pass
    • Flag
    • Fail

    Are barricades and warning signs in place in all required areas requiring restricted access?

    • Pass
    • Flag
    • Fail

    Are signs posted for any area where an entire building or area within the plant is "off limits"?

    • Pass
    • Flag
    • Fail

    Are Chain hoist being stored correctly?

    • Pass
    • Flag
    • Fail

    Are chain hoist protected from damage of moisture, heat, corrosion, and abuse?

    • Pass
    • Flag
    • Fail

    Are slings stored that protects them from damage from moisture, heat, corrosion, and abuse?

    • Pass
    • Flag
    • Fail

    Do slings have rated capacity on collar or tag?

    • Pass
    • Flag
    • Fail

    Are slings free of snags, nicks, kinks, or other distortions?

    • Pass
    • Flag
    • Fail

    Are sling hooks free of cracks and complete (all mechanical parts in place and functioning)?

    • Pass
    • Flag
    • Fail

    Are slings properly color-coded for the current time period?

    • Pass
    • Flag
    • Fail

    Are all machine guards adequate for protecting personne from exposure of injury and the guards properly secured?

    • Pass
    • Flag
    • Fail

    Are lubrication lines extended so as to allow lubrication from a safe location?

    • Pass
    • Flag
    • Fail

    Have the appropriate employees affixed a personal lock to the power sources, valves, etc?

    • Pass
    • Flag
    • Fail

    Have all energy sources been adequately addressed (e.g. blocking, chocking, relieving pressure)?

    • Pass
    • Flag
    • Fail

    Did the employees verify that the equipment was isolated?

    • Pass
    • Flag
    • Fail

    Did the employees follow all other requirements as outlined in the procedure?

    • Pass
    • Flag
    • Fail

    Is the LOTO board and binder being kept up and filled out?

    • Pass
    • Flag
    • Fail

    Are the correct locks being used correctly for what they are guarding?

    • Pass
    • Flag
    • Fail

    Do adequate storage locations exist for compressed gas cylinders?

    • Pass
    • Flag
    • Fail

    Are cylinders stored adequate distances from heat sources?

    • Pass
    • Flag
    • Fail

    Are oxygen cylinders stored a minimum of 20 feet away from flammable gas cylinders?

    • Pass
    • Flag
    • Fail

    Are the gauges on the regulators legible and in good working order?

    • Pass
    • Flag
    • Fail

    Are the cylinders properly secured?

    • Pass
    • Flag
    • Fail

    Is there signage for cylinders in area?

    • Pass
    • Flag
    • Fail

    Are hand tools in proper working order?

    • Pass
    • Flag
    • Fail

    Are tools clean/properly stored and organized?

    • Pass
    • Flag
    • Fail

    Are non-grounded tools clearly marked as double insulated?

    • Pass
    • Flag
    • Fail

    Are there ground prongs on all uninsulated portable power tools?

    • Pass
    • Flag
    • Fail

    Are the handles of shovels, hoes, hammers, striking tools and similar tools made of wood or fiberglass and free of cracks and breaks and are faces smooth and clean ?

    • Pass
    • Flag
    • Fail

    Do hand power tools have manufacturer guards in place and are automatic guards functional?

    • Pass
    • Flag
    • Fail

    Are personnel wearing a full face shield and safety glasses when using grinding equipment?

    • Pass
    • Flag
    • Fail

    Is the tool rest within an 1/8" of the wheel/stone?

    • Pass
    • Flag
    • Fail

    Is the grinding wheel running "true" and unbroken?

    • Pass
    • Flag
    • Fail

    Are all guards properly adjusted and secured in place?

    • Pass
    • Flag
    • Fail

    Are heaters positioned at least 10 feet away from combustible materials?

    • Pass
    • Flag
    • Fail

    Are lines and hoses suitable for LP gas use?

    • Pass
    • Flag
    • Fail

    Is there an approved regulator installed between the cylinder and the heater?

    • Pass
    • Flag
    • Fail

    Are individual heater fuel containers separated by at least 25 feet?

    • Pass
    • Flag
    • Fail

    Are LP gas cylinders stored outside on a solid surface and away from vehicular traffic?

    • Pass
    • Flag
    • Fail

    Are flammable material stored around heaters?

    • Pass
    • Flag
    • Fail

    Is there any accumulation of flammable materials?

    • Pass
    • Flag
    • Fail

    Are all exits and access points to the fire escapes and firefighting equipment clear of obstructions?

    • Pass
    • Flag
    • Fail

    Are all fire extinguishers' monthly inspections current and initialed?

    • Pass
    • Flag
    • Fail

    Are fire extinguishers mounted correctly

    • Pass
    • Flag
    • Fail

    Are structural members, stairways, handrails, and elevated working surfaces free of corrosion?

    • Pass
    • Flag
    • Fail

    Are eyewash and shower stations adequate and expiration tags legible?

    • Pass
    • Flag
    • Fail

    Are window and siding in tact and in good repair?

    • Pass
    • Flag
    • Fail

    Is all electrical equipment appropriately guarded and labeled?

    • Pass
    • Flag
    • Fail

    Are principle power switches labeled to show which units they control?

    • Pass
    • Flag
    • Fail

    Is non-conductive flooring available to stand on at switchboards and power control switches?

    • Pass
    • Flag
    • Fail

    Are all extension cords three prong grounding type and in good condition?

    • Pass
    • Flag
    • Fail

    Does each welder have a disconnect switch or breaker on supply system?

    • Pass
    • Flag
    • Fail

    Does each welder have a nameplate with electrical data?

    • Pass
    • Flag
    • Fail

    Are building ground conductors in good repair and solidly connected to the building steel?

    • Pass
    • Flag
    • Fail

    Is fixed equipment permanently grounded and permanently wired?

    • Pass
    • Flag
    • Fail

    Is portable equipment grounded with continuously monitored ground continuity check equipment?

    • Pass
    • Flag
    • Fail

    Are special electrical fixtures and equipment used in hazardous areas?

    • Pass
    • Flag
    • Fail

    Are all electrical panel doors, outlet and junction covers properly closed and secure?

    • Pass
    • Flag
    • Fail

    Are temporary power supply cords properly stored after use?

    • Pass
    • Flag
    • Fail

    Is electrical equipment stored away from water supply?

    • Pass
    • Flag
    • Fail

    Are Combustibles being stored on electrical panels?

    • Pass
    • Flag
    • Fail
Source: Gabbs - Premier Magnesia (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.