Back

4-Person High Speed (Detachable) Drive Terminal Pre-ops

Required procedure including required checklists, inspections and meter readings
Stevens Pass
09/09/2023

4-Person High Speed (Detachable) Drive Terminal Pre-ops

Required procedure including required checklists, inspections and meter readings

    General

    Date & Time

    Hours

    Control Voltage (V)

    Control Amperage (A)

    Weather

    Motor Room

    * = Visual Inspection

    Brake Motor ON

    • Pass
    • Flag
    • Fail

    Brake motor Voltage (V)

    Brake motor Amperage (A)

    Entry brush down/up per Weather Conditions

    Accel/ Decel Belts, Tires, Rails

    • Pass
    • Flag
    • Fail

    PTO Belts, Sheaves

    • Pass
    • Flag
    • Fail

    Safety/ Limit Switches Exercised & Reset

    • Pass
    • Flag
    • Fail

    Drive Machinery belts, mounts, alignment

    • Pass
    • Flag
    • Fail

    Gear Box oil level

    • Pass
    • Flag
    • Fail

    Planetary oil level

    • Pass
    • Flag
    • Fail

    Battery Chargers

    • Pass
    • Flag
    • Fail

    Batteries

    • Pass
    • Flag
    • Fail

    *Fire Extinguishers; Present, Charged

    • Pass
    • Flag
    • Fail

    *Auxiliary

    * = Visual Inspection

    Fuel Level

    Fuel transfer pump functioning

    • Pass
    • Flag
    • Fail

    Oil, Coolant, ATF levels/ leaks

    • Pass
    • Flag
    • Fail

    Block Heater functioning

    • Pass
    • Flag
    • Fail

    Coupling: Instructions, chain, master link, cotters, pliers

    • Pass
    • Flag
    • Fail

    Brakes

    * = Visual Inspection

    Oil Level

    • Pass
    • Flag
    • Fail

    *Inspect All Brakes

    • Pass
    • Flag
    • Fail

    *Breaking surfaces, pads & hoses

    • Pass
    • Flag
    • Fail

    *Operating position for bypass levers

    • Pass
    • Flag
    • Fail

    *High Speed Backstop in Operating Position

    • Pass
    • Flag
    • Fail

    Controls

    Exercise & Reset STOP buttons x4

    • Pass
    • Flag
    • Fail

    Exercise & Reset EMERGENCY STOP x4

    • Pass
    • Flag
    • Fail

    Stop Gate operating position & functional

    • Pass
    • Flag
    • Fail

    Tower Circuit switch = Both

    • Pass
    • Flag
    • Fail

    Run lift on Med 2x longest span before Fast

    • Pass
    • Flag
    • Fail

    Lift Speed on Fast FPM

    Stopping Distance from Fast STOP

    Stopping Distance from Fast Emergency Stop

    Secure Seat Inspection complete

    • Pass
    • Flag
    • Fail

    Test designated controls while running

    • Pass
    • Flag
    • Fail

    Notes

    Date

    Signature

    Click here to sign
Source: Stevens Pass (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Global Procedure Library is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.