    HYDRAULIC UNIT

    Section #2LUBRICATION UNIT

    SPINDLE, LUBRICATION

    PNEUMATIC SYSTEM

    AIR BLOW & WHEN TOOL UNCLAMP FROM SPINDLE

    • Pass
    • Flag
    • Fail

    ADJUST AIR LUBRICATOR & DRIP AMOUNT

    • Yes
    • No
    • N / A

    CHECK PNEUMATIC SYSTEM FOR LEAKS

    • Pass
    • Flag
    • Fail

    CHECK SPINDLE FLANGE AIR PURGE

    • Pass
    • Flag
    • Fail

    ELECTRICAL

    INSPECT ALL CANNON CONNECTORS

    • Pass
    • Flag
    • Fail

    CHECK SWITCH FUNCTIONS

    • Pass
    • Flag
    • Fail

    INSPECT ALL INDICATOR LAMPS

    • Pass
    • Flag
    • Fail

    CHECK COOLING FANS IN ELECTRICAL BOX

    • Pass
    • Flag
    • Fail

    CHECK SEAL TIGHT CONNECTORS

    • Pass
    • Flag
    • Fail

    CHECK OPERATION OF SPINDLE MOTOR FA

    • Pass
    • Flag
    • Fail

    PALLET CHANGER

    CHECK PALLET CHANGER ALIGNMENT

    • Pass
    • Flag
    • Fail

    CHECK CAM FOLLOWER ON PALLET BASE

    • Pass
    • Flag
    • Fail

    CHECK CAM FOLLOWER ON PALLET ARM

    • Pass
    • Flag
    • Fail

    INSPECT WARE PLATE ON PALLET

    • Pass
    • Flag
    • Fail

    MISCELLANEOUS

    CHECK COUNTER BALANCE CHAIN

    • Pass
    • Flag
    • Fail

    CHECK COUNTER BALANCE CYLINDER FOR LEAKS

    • Pass
    • Flag
    • Fail

    CHECK EMERGENCY STOP

    • Pass
    • Flag
    • Fail

    4TH AXIS

    CHECK & ADJUST BACKLASH

    • Pass
    • Flag
    • Fail

    INSPECT DC MOTOR BRUSHES

    • Pass
    • Flag
    • Fail

    HIGH SPEED SPINDLE

    ( MAIN AIR SUPPLY )

    CHECK MAIN AIR LUBE UNIT FOR WATER OR SLUDGE

    • Pass
    • Flag
    • Fail

    CHECK AIR FILTER ON AIR DRYER

    • Pass
    • Flag
    • Fail

    CHECK OIL MIST REMOVER IS CLEAN

    • Pass
    • Flag
    • Fail

    CHECK AIR PRESSURE IS 5 KG/CM2

    • Pass
    • Flag
    • Fail

    ( OIL AIR UNIT )

    CHECK AIR PRESSURE ( 4 KG/CM2. )

    • Pass
    • Flag
    • Fail

    CHECK OIL TANK ( CLEAN )

    • Pass
    • Flag
    • Fail

    CHECK AIR BUBBLES IN OIL

    • Pass
    • Flag
    • Fail

    THE OIL IS MOBIL D.T.E. LIGHT 24

    • Yes
    • No
    • N / A

    CHECK OIL AIR UNIT FOR LEAKS

    • Pass
    • Flag
    • Fail

    CHECK OIL AIR UNIT IS WORKING CORRECTLY

    • Pass
    • Flag
    • Fail

    ( SPINDLE OIL COOLER )

    CHECK COOLER SETTING

    • Pass
    • Flag
    • Fail

    CHECK AIR FILTER

    • Pass
    • Flag
    • Fail

    ( AIR DRYER )

    MAIN SWITCH IS ON

    • Yes
    • No
    • N / A

    CHECK TO MAKE SURE WARM AIR COMES OUT

    • Yes
    • No
    • N / A

    ( MIXING VALVE )

    CHECK OIL OR AIR IS NOT LEAKING AROUND VALVE

    • Pass
    • Flag
    • Fail

    CHECK ALL CONNECTIONS ARE TIGHTEN

    • Pass
    • Flag
    • Fail

    CHECK THE AMOUNT OF OIL COMING OUT OF VALVE

    • Pass
    • Flag
    • Fail

    X AXIS

    CHECK THRUST BEARINGS

    • Pass
    • Flag
    • Fail

    CHECK & ADJUST BACKLASH

    • Pass
    • Flag
    • Fail

    PULL BACK GUARDS & INSPECT WAY SURFACES

    • Pass
    • Flag
    • Fail

    INSPECT DC MOTOR BRUSHES

    • Pass
    • Flag
    • Fail

    INSPECT AXIS LUBE SYSTEM

    • Pass
    • Flag
    • Fail

    INSPECT GUARDS

    • Pass
    • Flag
    • Fail

    INSPECT WIPERS

    • Pass
    • Flag
    • Fail

    Y AXIS

    CHECK THRUST BEARINGS

    • Pass
    • Flag
    • Fail

    PULL BACK GUARDS & INSPECT WAY SURFACES

    • Pass
    • Flag
    • Fail

    PULL BACK GUARDS & INSPECT WAY SURFACES

    • Pass
    • Flag
    • Fail

    INSPECT DC MOTOR BRUSHES

    • Pass
    • Flag
    • Fail

    INSPECT AXIS LUBE SYSTEM

    • Pass
    • Flag
    • Fail

    INSPECT GUARDS

    • Pass
    • Flag
    • Fail

    INSPECT WIPERS

    • Pass
    • Flag
    • Fail

    Z AXIS

    CHECK BACKLASH IN BALL SCREW NUT

    • Pass
    • Flag
    • Fail

    CHECK THRUST BEARINGS

    • Pass
    • Flag
    • Fail

    CHECK & ADJUST BACKLASH

    • Pass
    • Flag
    • Fail

    ADJUST JIBS (IF NEEDED)

    • Pass
    • Flag
    • Fail

    PULL BACK GUARDS & INSPECT WAY SURFACES

    • Pass
    • Flag
    • Fail

    INSPECT DC MOTOR BRUSHES

    • Pass
    • Flag
    • Fail

    T AXIS LUBE SYSTEM

    • Pass
    • Flag
    • Fail

    INSPECT GUARDS

    • Pass
    • Flag
    • Fail

    INSPECT WIPERS

    • Pass
    • Flag
    • Fail

    SITE COMMENTS

    CUSTOMER PRINT NAME

    Technician Signature

    Click here to sign
Source: Christensen Arms (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Global Procedure Library is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.