Annual RO Filter check/replacement (Reo Pure system)
This annual maintenance procedure covers the inspection and replacement of filters in the Reo Pure reverse osmosis system to support efficient operation and consistent water quality.
Annual RO Filter check/replacement (Reo Pure system)
The aim is to maintain effective water filtration and reliable system performance through yearly inspection and replacement of filters as required. This maintenance helps identify clogged or deteriorated filters, maintain consistent water flow and quality, and extend the system’s service life.
Inspect rubber O ring for any damage such as cracks, splits and flat spots.
Inspect rubber O ring for any damage such as cracks, splits, or flat spots.
Observe and record tds on system controller
RO membranes should be replaced once TDS reaches 14 ppm or 20 us.
RO membranes replaced
List of other components, inspected or replaced during service.
Source: Cambridge technologies Global Org (Community Member)