Greasing Procedure for Willexa Motor
This procedure is used to grease the Willexa motor bearings correctly, so wear is prevented and the motor stays reliable.
Greasing Procedure for Willexa Motor
This procedure outlines the greasing of the Willexa motor bearings to keep the motor running reliably. It guides the technician through gathering tools, identifying the drive-end and non-drive-end grease points, removing the relief plug, applying grease, briefly running the motor to distribute it, and restoring power, followed by sign-off.
Preparation
Tools and Materials
Greasing Procedure
1. Identify Grease Points
2. Remove Grease Relief Plug
3. Apply Grease
4. Run Motor Briefly
5. Remove LOTO
Sign off
Signature:
Click here to sign
Source: [GA] Pine Ridge - Captis Energy (Community Member)