This monthly calibration procedure verifies that all power supply voltage outputs on the AS24-01 system are within the required tolerances. Performing this calibration ensures accurate machine performance, supports product quality, and helps identify electrical issues before they affect production.
AS24-01 Monthly Calibration
This monthly calibration procedure verifies that all power supply voltage outputs on the AS24-01 system are within the required tolerances. Performing this calibration ensures accurate machine performance, supports product quality, and helps identify electrical issues before they affect production.
Calibration Procedure
40. Measure the voltage at the 24.00vdc (2005PWS) power supply. (23.8vdc - 24.2vdc)
Meter name
Unit
50. Measure the voltage at the 24.00vdc (2006PWS) power supply. (23.9vdc - 24.3vdc)
Meter name
Unit
60. Measure the voltage at the 24.00vdc (2007PWS) power supply. (23.9vdc - 24.3vdc)
Meter name
Unit
70. Measure the voltage at the 24.00vdc (2008PWS) power supply. (23.9vdc - 24.3vdc)
Meter name
Unit
80. Measure the voltage at the 24.00vdc (2014PWS) power supply. (23.9vdc - 24.3vdc)
Meter name
Unit
90. Measure the voltage at the 24.00vdc (2105PWS)(Enclosure 2) power supply. (23.9vdc - 24.3vdc)
Meter name
Unit
100. Measure the voltage at the 24.00vdc (2106PWS)(Enclosure 2) power supply. (23.9vdc - 24.3vdc)
Meter name
Unit
110. Measure the voltage at the 24.00vdc (2123PWS)(Enclosure 2) power supply. (23.9vdc - 24.3vdc)
Meter name
Unit
120. Measure the voltage at the 12.00vdc (8301PWS) power supply. (11.8vdc - 12.2vdc)
Meter name
Unit
130. Measure the voltage at the 12.00vdc (8501PWS) power supply. (11.8vdc - 12.2vdc)
Meter name
Unit
190. Enter the ID# of the voltage meter that was used.
200. Sign Off