Pearson Daily Case Former PM

This procedure provides a daily preventive maintenance checklist for the Pearson Case Former, beginning with equipment isolation per Chewy’s Hazardous Energy Control Policy and covering air prep (drain filters, verify ~80 psi), cleanliness, sensor care, and inspection of vacuum cups/hoses, bulbs, regulators, and indicators. It also specifies taper head tasks—inspect and clean cutter blades, oil blade-guard pads, listen for abnormal noise/vibration, and verify all rollers (especially the split roller) move freely.
DAY1 Dayton, OH- Chewy
10/06/2025

Pearson Daily Case Former PM

This procedure provides a daily preventive maintenance checklist for the Pearson Case Former, beginning with equipment isolation per Chewy’s Hazardous Energy Control Policy and covering air prep (drain filters, verify ~80 psi), cleanliness, sensor care, and inspection of vacuum cups/hoses, bulbs, regulators, and indicators. It also specifies taper head tasks—inspect and clean cutter blades, oil blade-guard pads, listen for abnormal noise/vibration, and verify all rollers (especially the split roller) move freely.

    Authorized Team Members are required to perform equipment isolation in accordance with Chewy's Hazardous Energy Control Policy as well as complying with the restrictions and limitations imposed upon them during the use of lockout tagout. Disciplinary action will be taken against all violators according to Chewy's disciplinary policy.

    Check the Air Prep Unit. Drain any water from the filter.

    • Pass
    • Flag
    • Fail

    Check the condition of the vacuum cups

    • Pass
    • Flag
    • Fail

    Inspect the flexible vacuum hose for wear.

    • Pass
    • Flag
    • Fail

    Check the bulbs, regulators and indicators.

    • Pass
    • Flag
    • Fail

    Check the cleanliness of the mechanical areas.

    • Pass
    • Flag
    • Fail

    Keep sensor eyes clean.

    • Pass
    • Flag
    • Fail

    Check the air pressures, System pressure is 80 psi

    • Pass
    • Flag
    • Fail

    Taperhead Tasks:

    a. Inspect Cutter Blades for wear. Clean with solvent.

    • Pass
    • Flag
    • Fail

    b. Blade Guard Oiler Pads should be oiled using lightweight oil.

    • Pass
    • Flag
    • Fail

    c. Listen to taper head operation for unusual noise or vibration.

    • Pass
    • Flag
    • Fail

    d. Inspect all rollers for freedom of movement. The split roller, in particular, is prone to becoming gummed up. Clean as necessary.

    • Pass
    • Flag
    • Fail
Source: DAY1 Dayton, OH- Chewy (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.