INSPECTION - Contractor 1245 Dust Collectors - Quarterly
This procedure outlines the quarterly inspection of the Contractor 1245 dust collectors to identify maintenance needs and support reliable operation.
INSPECTION - Contractor 1245 Dust Collectors - Quarterly
The aim of this quarterly inspection is to assess the condition and performance of the Contractor 1245 dust collectors, identify any signs of wear or malfunction, and ensure they continue to collect dust effectively and operate safely. Procedure Reviewed: Sep 2026
778 - Inspection, Maintenance and Remove/Replace Cartridge Dust Collector 779 - Changing Dust Drums on Dust Collectors at Coating Centers
Cubicle Dust Collectors
Grit Blast/Glass Bead Dust Collectors
Dust Collector 01G: DCE Vokes UMA102G3 [85-1124-11]
Record differential pressure (Inches of Water).
if the answer is "< 0.5 "
Differential pressure is out of tolrance.
Fail if below 0.5 in/H20
if the answer is "> 6 "
Differential pressure is out of tolerance.
Fail if above 6.0 in/H20.
Timer sequencing row by row properly.
If dust collector does not have a timer sequencer, select "PASS".
Solenoids operating properly.
Diaphragm valves firing properly.
Hopper discharge device operating properly.
No visible stack emissions.
All filters are serviceable and present.
Pictures (As required)
Add or drag pictures
Additional Notes (As required)
Inspections verified/completed by:
(Signature)
Click here to sign
Name of company representative completing inspections.
(First and Last Name)