This procedure provides step-by-step instructions for diagnosing and resolving issues related to the CHC Vector Drive system in Haas machines, ensuring efficient troubleshooting and maintenance.
The Gund Co. ALB
03/26/2024

Haas CHC Vector Drive Troubleshooting Guide

This procedure provides step-by-step instructions for diagnosing and resolving issues related to the CHC Vector Drive system in Haas machines, ensuring efficient troubleshooting and maintenance.

    Warning: Only qualified personnel should perform electrical tests.

    CHC Vector Drive

    • VectorDrive.webp

    Electrical Diagram

    • Electricaldiagram.png

    Perform visual inspection of vector drive for any visible damage

    • Pass
    • Flag
    • Fail

    Short Circuit Inspection 1

    • ShortCircuitInspection1.png

    Record Terminal #4 to Ground Ohm's

    • Terminal4togroung.png

    Record Terminal #5 to Ground Ohm's

    • Terminal5.png

    Record Terminal #6 to Ground Ohm's

    • Terminal6.png

    Record Terminal #2 to Terminal #9 Ohm's

    • Terminal2to9.png

    Record Terminal #2 to Terminal #10 Ohm's

    • Terminal2to10.png

    Record Terminal #2 to Terminal #11 Ohm's

    • Terminal2to11.png

    Record Terminal #3 (-) to Terminal #9 Ohm's

    • terminal3to9.png

    Record Terminal #3 (-) to Terminal #10 Ohm's

    • terminal3to10.png

    Record Terminal #3 (-) to Terminal #11 Ohm's

    • terminal3to11.png

    Record terminal 3 (-) with black lead to terminal 1 with red lead.

    • terminal1to3.png

    Regen Load Test. Disconnect terminal 1 and 2. Record Ohm's

    • Regen.png
    • Regen1.png

    Record DC Buss Voltage

    • Terminal2and3voltage.png
    • Terminal2and3voltagedescription.png
    • Ampliferdiodetest.png

    Cooling fan operational? Going correct direction?

    • coolingfan.png
    • Overtemp.png
    • Pass
    • Flag
    • Fail

    Record Incoming Voltage Terminal 1 and 2

    • Inpurvoltagetest.png

    Record Incoming Voltage Terminal 1 and 3

    • Inpurvoltagetest.png

    Record Incoming Voltage Terminal 2 and 3

    • Inpurvoltagetest.png

    Record Terminal 3 and 9 voltage

    • Unbalancedoutputinspection.png

    Record Terminal 3 and 10 voltage

    • Unbalancedoutputinspection.png

    Record Terminal 3 and 11 voltage

    • Unbalancedoutputinspection.png
Source: The Gund Co. ALB (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Global Procedure Library is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.