Back

Building Safety Inspection Checklist

Use this checklist to understand the current situation of the building/property. You can also predict any problems in advance, therefore avoid any future hazards or accidents.
MaintainX
07/21/2022

Building Safety Inspection Checklist

Use this checklist to understand the current situation of the building/property. You can also predict any problems in advance, therefore avoid any future hazards or accidents.

    Building/Department(s):

    Date:

    Inspectors:

    Building Coordinator:

    General-All Areas

    Are all ceiling tiles in place and in good condition?

    • Pass
    • Flag
    • Fail

    . Is all furniture in good/stable condition and properly adjusted?

    • Pass
    • Flag
    • Fail

    Are wall-mounted book cases free of excessive material on top and and not overloaded? (Chemicals & heavy items should not be stored above head height (6 feet)).

    • Pass
    • Flag
    • Fail

    Are all walking or working surfaces free of tipping/slipping hazards?

    • Pass
    • Flag
    • Fail

    Are emergency phone numbers and procedures posted at or near telephones?

    • Pass
    • Flag
    • Fail

    Are all fans equipped with a blade guard with openings no greater paper, plastic, etc.)? than ½ inch?

    • Pass
    • Flag
    • Fail

    Is consumption of food, beverage, etc., prohibited where required?

    • Pass
    • Flag
    • Fail

    General – Shops

    Are machine and belt guards in place and in good condition?

    • Pass
    • Flag
    • Fail

    Is pedestal machinery securely anchored to the floor?

    • Pass
    • Flag
    • Fail

    Is equipment properly maintained and adjusted to prevent personal injury and equipment damage?

    • Pass
    • Flag
    • Fail

    Are compressed air nozzles at the correct pressure of 30 psi or less?

    • Pass
    • Flag
    • Fail

    Is all piping appropriately identified as to contents/direction of flow?

    • Pass
    • Flag
    • Fail

    Are hot pipes and surfaces guarded against contact and clearly 2. Are protective valve caps in place when cylinder is not in use? marked “HOT”?

    • Pass
    • Flag
    • Fail

    Are areas requiring use of protective equipment (e.g., Eye Protection 4. Are only chemically compatible cylinders stored together? Required, etc.) adequately posted with warning signs and enforced?

    • Pass
    • Flag
    • Fail

    Is damaged/malfunctioning equipment tagged “OUT OF SERVICE”?

    • Pass
    • Flag
    • Fail

    Exits/Corridors

    Are all corridors unobstructed?

    • Pass
    • Flag
    • Fail

    Are all exit doors unobstructed?

    • Pass
    • Flag
    • Fail

    Are exit signs posted and properly illuminated to clearly indicate 2. Is the required personal protective equipment worn? exits?

    • Pass
    • Flag
    • Fail

    Are all exit doors able to be opened from the inside without special knowledge/keys?

    • Pass
    • Flag
    • Fail

    Are exit doors free of slide bolts or locks?

    • Pass
    • Flag
    • Fail

    Electrical

    Is there at least three (3) feet clearance in front of electrical panels/breaker boxes?

    • Pass
    • Flag
    • Fail

    Are electric hand tools properly grounded/double insulated?

    • Pass
    • Flag
    • Fail

    Is the area free of extension cords?

    • Pass
    • Flag
    • Fail

    Is all electrical equipment plugged directly into wall outlets?

    • Pass
    • Flag
    • Fail

    Are all cords/plugs free from damage or deterioration?

    • Pass
    • Flag
    • Fail

    Are switches and circuit breakers properly identified as to the J. Railing/Elevated Work Areas service they are in and to what they control?

    • Pass
    • Flag
    • Fail

    . Are circuit breaker panels free of combustible materials?

    • Pass
    • Flag
    • Fail

    Are covers plates in place on junction boxes to eliminate exposed wiring?

    • Pass
    • Flag
    • Fail

    Are “WARNING HIGH VOLTAGE” signs installed on high voltage 3. Are standard guardrails provided on elevated platforms? enclosures for systems rated 600V or over?

    • Pass
    • Flag
    • Fail

    Is all electrical, including light fixtures, protected from physical damage by enclosure/guards?

    • Pass
    • Flag
    • Fail

    Emergency Equipment

    . Is emergency equipment (alarm pull boxes, eyewashes, showers, 1. Are portable ladders in good repair and safe to use? etc.) accessible and not blocked by equipment?

    • Pass
    • Flag
    • Fail

    Are emergency eyewashes provided in the required chemical areas?

    • Pass
    • Flag
    • Fail

    Are emergency showers provided in the required chemical areas?

    • Pass
    • Flag
    • Fail

    Is all emergency equipment in good condition?

    • Pass
    • Flag
    • Fail

    . Are spill kits accessible and fully stocked per list?

    • Pass
    • Flag
    • Fail

    Storage – Genera

    Is good housekeeping practiced in work area (Is it free of debris, 3. Are load limits clearly posted in the area? combustibles, obstructions? Are aisles maintained?)?

    • Pass
    • Flag
    • Fail

    Is storage adequately supported/stable to avoid tipping/falling?

    • Pass
    • Flag
    • Fail

    Is there at least two (2) feet clearance between stacked materials and ceiling light?

    • Pass
    • Flag
    • Fail

    Storage – Fire Protection

    is the storage of combustibles in the work area held to a minimum to avoid a fire hazard?

    • Pass
    • Flag
    • Fail

    Is clearance of at least 18 inches maintained around fire sprinkler heads?

    • Pass
    • Flag
    • Fail

    Are flammable/combustible liquids in excess of one day’s operational supply kept in approved flammable materials storage (FMS) cabinets?

    • Pass
    • Flag
    • Fail

    Are all FMS cabinets free of combustible materials (cardboard, 6. Are all fans equipped with a blade guard with openings no greater paper, plastic, etc.)?

    • Pass
    • Flag
    • Fail

    Are all flammable containers properly closed/covered to control vapors?

    • Pass
    • Flag
    • Fail

    Are all flammable/combustible containers properly labeled/ identified?

    • Pass
    • Flag
    • Fail

    Are all refrigerators used for storage of flammable/combustible liquids/materials approved and explosion proof?

    • Pass
    • Flag
    • Fail

    Are flammable/combustible liquids returned to approved flamm- able liquid storage cabinets at the end of the workday?

    • Pass
    • Flag
    • Fail

    Storage – Compressed Glass Cylinders

    Are all cylinders properly secured with straps or chains to prevent tipping/falling?

    • Pass
    • Flag
    • Fail

    Are protective valve caps in place when cylinder is not in use?

    • Pass
    • Flag
    • Fail

    Are empty and full cylinders stored separately?

    • Pass
    • Flag
    • Fail

    Are only chemically compatible cylinders stored together?

    • Pass
    • Flag
    • Fail

    Are cylinder contents adequately labeled and easily seen?

    • Pass
    • Flag
    • Fail

    Is the correct regulator being used for the cylinder service?

    • Pass
    • Flag
    • Fail

    Are highly toxic gases stored in vented gas cabinets?

    • Pass
    • Flag
    • Fail

    Personal Protective Equipment

    . Is the requirement of use of protective equipment enforced?

    • Pass
    • Flag
    • Fail

    Is the required personal protective equipment worn?

    • Pass
    • Flag
    • Fail

    When not in use, is personal protective equipment properly maintain/stored?

    • Pass
    • Flag
    • Fail

    . Is personal protective equipment readily available for all personnel including visitors to the area?

    • Pass
    • Flag
    • Fail

    Is all personal protective equipment free from damage and deterioration?

    • Pass
    • Flag
    • Fail

    Are all employees using respiratory protection properly trained and authorized by EH&S?

    • Pass
    • Flag
    • Fail

    Is self-contained breathing equipment properly maintained/ inspected?

    • Pass
    • Flag
    • Fail

    Railing/Elevated Work Areas

    Are drain openings/pits in the floor or walking surfaces guarded to prevent tripping/slipping?

    • Pass
    • Flag
    • Fail

    Are toeboards in place on elevated platforms to prevent objects from falling off the platform?

    • Pass
    • Flag
    • Fail

    Are standard guardrails provided on elevated platforms?

    • Pass
    • Flag
    • Fail

    Are handrails provided and in good condition on stairways?

    • Pass
    • Flag
    • Fail

    Are there provisions for safe access to elevated machinery/ equipment?

    • Pass
    • Flag
    • Fail

    Ladders

    Are portable ladders in good repair and safe to use?

    • Pass
    • Flag
    • Fail

    Are mobile ladder stands in good condition?

    • Pass
    • Flag
    • Fail

    Are standard guardrails provided on elevated platforms?

    • Pass
    • Flag
    • Fail

    Are handrails provided and in good condition on stairways?

    • Pass
    • Flag
    • Fail

    Forklifts

    Are defective forklifts taken out of service and tagged “DO NOT USE”?

    • Pass
    • Flag
    • Fail

    Are forklift inspection forms current and maintained in a file?

    • Pass
    • Flag
    • Fail

    Are load limits clearly posted in the area?

    • Pass
    • Flag
    • Fail

    Are forklift operating rules clearly posted in the area?

    • Pass
    • Flag
    • Fail

    Are all operators trained and authorized?

    • Pass
    • Flag
    • Fail

    Fire Protection

    Are there current welding permits displayed in welding area?

    • Pass
    • Flag
    • Fail

    Are all self-closing doors operational?

    • Pass
    • Flag
    • Fail

    Are walls and floors free of holes/penetrations?

    • Pass
    • Flag
    • Fail

    Are no smoking regulations clearly posted and being followed in “NO SMOKING” areas?

    • Pass
    • Flag
    • Fail

    Are fire extinguishers and signs clearly visible?

    • Pass
    • Flag
    • Fail

    Is access to fire extinguishers clear and unobstructed?

    • Pass
    • Flag
    • Fail

    Are all extinguishers in place and properly mounted?

    • Pass
    • Flag
    • Fail

    Are all extinguishers properly inspected (monthly) and maintained (annually)?

    • Pass
    • Flag
    • Fail

    Training

    Have personnel been trained in the use of personal protective equipment?

    • Pass
    • Flag
    • Fail

    Are all employees trained in hazardous substances safety?

    • Pass
    • Flag
    • Fail

    Have personnel working in high noise areas been trained in hearing conservation?

    • Pass
    • Flag
    • Fail

    Have employees who use respirators been trained, fit tested, and received the required health monitoring examination?

    • Pass
    • Flag
    • Fail

    Are employees who use self-contained breathing apparatus properly trained and authorized?

    • Pass
    • Flag
    • Fail

    Evac Plans

    • Pass
    • Flag
    • Fail

    Computer Rooms

    Are combustibles stored in approved, enclosed metal cabinets?

    • Pass
    • Flag
    • Fail

    Is combustible waste, e.g., trash containers, cardboard boxes, etc., removed from the room daily or more often as needed?

    • Pass
    • Flag
    • Fail

    Is the computer room free of flammable/combustible liquids?

    • Pass
    • Flag
    • Fail

    Are computer tapes stored in approved, enclosed metal cabinets?

    • Pass
    • Flag
    • Fail

    Is the raised floor free of unsealed cable holes?

    • Pass
    • Flag
    • Fail

    Is the access to fire suppression and alarm systems unobstructed?

    • Pass
    • Flag
    • Fail

    Are floor tile pullers available and mounted?

    • Pass
    • Flag
    • Fail

    Are doors to the peripheral rooms closed?

    • Pass
    • Flag
    • Fail

    Is paper stored in computer room limited to a one day supply?

    • Pass
    • Flag
    • Fail

    Is the room free of repair shop operations?

    • Pass
    • Flag
    • Fail

    Is the room free of soldering irons?

    • Pass
    • Flag
    • Fail

    Is the room free of coffee makers, popcorn machines, electric floor/space heaters, etc.?

    • Pass
    • Flag
    • Fail

    Are “NO SMOKING” signs posted and being enforced in computer rooms?

    • Pass
    • Flag
    • Fail

    Explanation/Comments

Source: MaintainX (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Global Procedure Library is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.