Split System Preventive Maintenance Checklist

This procedure is recommended to be done every quarter. Performing all maintenance procedures and inspections at the recommended intervals will prolong the life of the system and minimize the possibility of malfunctions.
Hobby Center of the Preforming Arts
06/22/2025

Split System Preventive Maintenance Checklist

This procedure is recommended to be done every quarter. Performing all maintenance procedures and inspections at the recommended intervals will prolong the life of the system and minimize the possibility of malfunctions.

    Quarterly Maintenance

    Before starting the following checks, turn the unit OFF and lock the main power disconnect switch in the open position. Disconnect all power sources, including remote disconnects, water, air, or mechanical before servicing. Failure to disconnect all power sources before servicing could result in death or serious injury. Follow proper lockout/tagout procedures to ensure the power can not be inadvertently energized. Verify that no power is present.

    In-doors side of the system: Will need to remove all access panels for proper inspection

    • airhandler.jpg

    Units housing/access panels condition

    Return air filters.

    Condensation pump/pan, piping and insulation

    Control wiring

    Refrigerant piping and insulation

    Evaporator Coil

    Blower Wheel

    Blower Motor

    Reinstall all panels on the indoor portion of system making sure that all retaining screws are reinstalled. Clean debris/trash up in the area and remove all tools

    • Condensor.jpg

    Outdoor side of system: Will need to remove all access panels for proper inspection

    Units housing/access panels condition

    Control wiring

    Condenser Coil

    Refrigerant piping and insulation

    Fan Motor/blade

    Reinstall all panels on outside portion of system making sure that all retaining screws are reinstalled. Clean debris/trash up in the area and remove all tools

    Recheck inside and out to make sure system is clear and ready to be reenergized.

    After restoring all power to the system turn it on. With the unit running, check and record the following:

    Amperage on indoor section of system

    Indoor Ambient air temp

    Return air temp

    Outdoor Ambient air temp

    Superheat Temp

    Subcooling Temp

    Amperage on outdoor section of system

    Final Process: Put all equipment and tools back in its proper storage location. Close out work order

    Employee that completed PM

    Click here to sign

    Date of completion

Source: Hobby Center of the Preforming Arts (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.