Compression Test Fire
This procedure outlines the essential steps for conducting a controlled compression test fire on a compressor unit, including safety checks, valve alignment, startup verification, and performance monitoring. This procedure ensures the unit operates safely and correctly under load, helping identify issues before the equipment is placed into service.
Compression Test Fire
This procedure outlines the essential steps for conducting a controlled compression test fire on a compressor unit, including safety checks, valve alignment, startup verification, and performance monitoring. This procedure ensures the unit operates safely and correctly under load, helping identify issues before the equipment is placed into service.
Unit Information
Compressor Unit Number
Date
Technican(s)
Starting Hours on Engine
Starting Hours on Compressor
Fire Extinguisher #1 Visual Inspection (Seal, UL, Damage)
Fire Extinguisher #1 Date Inspection
Fire Extinguisher #2 Visual Inspection (Seal, UL, Damage)
Fire Extinguisher #2 Date Inspection
Power-Off Checks
Inspect 1st Stage Scrubber for Liquid
Inspect 2nd Stage Scrubber for Liquid
Inspect 3rd Stage Scrubber for Liquid
Inspect Sight Glass on the Oil Catch Tank
Check Engine Oil via Dipstick
Check Oil Day (Makeup) Level
Valve Alignment Verification
Verify Air is Isolated from Fuel Gas System
Verify Natural Gas Fuel System Valve Alignment
Verify Suction Hose Connection
If a loaded test fire is being completed.
Verify Discharge Hose Connection
If a loaded test fire is being completed.
Power-On Checks
Check Battery Voltage on CAT Panel
Verify it is less than 24V. Enter Voltage Reading.
Verify Proper Ignition Timing for Fuel Source on CAT Panel
Verify Instrument Air Pressure is below 80 PSI
If it is above this range, adjust the regulator
Verify Fuel Pressure to Unit
Cycle the Manual Recycle (Bypass) Valve
If loaded test fire is being completed
Cycle the Manual Purge Valve
If loaded test fire is being completed
Cycle Through 1st, 2nd, & 3rd Stage
Verify all automated valved actuate during transition. If one fails, unit will auto-shutdown.
Starting the Unit
Manually Set to 1st Stage for Compression
Inspect Unit for Oil & Coolant Leaks
Describe leak level and location if applicable
Inspect Unit for Abnormal Noises
Describe issue if applicable
Verify Engine Speed Ramps up to
Verify Coolant Temps are above 130 F
Ramp Engine Speed to 1750 RPMs
Monitor Compressor Vibration
Record highest vibration readings
Monitor Engine Vibration
Record highest vibration readings
Monitor Cooler Vibration
Record highest vibration readings
Loading Unit (If Applicable)
Verify Recirculation Tank Regulators are set to
Load Start Time
Load End Time
Monitor Cylinder Temps do NOT exceed 300 F
Parameter Checks
1st Stage DE Suction Pressure (PSIG)
1st Stage DE Suction Temperature (F)
1st Stage NDE Suction Pressure (PSIG)
1st Stage NDE Suction Temperature (F)
1st Stage DE Discharge Pressure (PSIG)
1st Stage DE Discharge Temperature (F)
1st Stage NDE Discharge Pressure (PSIG)
1st Stage NDE Discharge Temperature (F)
2nd Stage Suction Temperature (F)
Verify Coolant Level is Adequate
Verify Oil Day (Makeup) Tank Level is Adequate
Unit Shut Down
If loaded test fire is being completed
Ending Hours on Engine
Ending Hours on Compressor
Notes about Test Fire