Back

Ski Lift Inspection Requirements, Frequency, and Methods - Off-season Inspection (Resort)

Ski resorts are required to follow state inspection requirements and those mandated by their insurance companies.
MaintainX
03/11/2023

Ski Lift Inspection Requirements, Frequency, and Methods - Off-season Inspection (Resort)

Ski resorts are required to follow state inspection requirements and those mandated by their insurance companies.

    Reference document: https://catsr.vse.gmu.edu/SYST490/495_2018_SkiLift/SkiLift_Final_Report.pdf - Page 10 Section 1.5

      In terms of inspection difficulty, 82% of the ski lift components listed below can be visually inspected without removing any shields. The communication line and the ski lift tower base require special inspection procedures. The comm line is held in a watertight enclosure that is checked every 3-5 years. However, electric faults in the comm line are indicated in the terminal’s control system which is checked daily. The ski lift tower base is examined for cracks using X-ray imaging every 5-10 years at Bryce

      The scope of the system’s capabilities exclude components that can be inspected from fault indications or in the terminal, components that require the removal of covers, or tactile inspections. The red underlined components in the table below indicate which components are within scope for visual inspection. Gaps in system capabilities for the tactile inspection of these components can be performed during regular tower maintenance, such as greasing.

      Table 4: Visual versus Tactile Inspections

      • Table4.jpg

        For comparison, the current inspection procedures for Bryce Resort and system capabilities are summarized below.

        Ski Lift Tower Structure

        Current Inspection Method

        Climb up tower and check for cracks or corrosion

        • Pass
        • Flag
        • Fail

        Check around base from the ground for corrosion and cracks visually

        • Pass
        • Flag
        • Fail

        System Capabilities

      Source: MaintainX (Community Member)

      Please note that any procedure, checklist, or other document available in the MaintainX Global Procedure Library is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.