Monthly Engineering Safety Checks
This checklist is crucial for preventing accidents, ensuring structural integrity, and minimizing downtime, ultimately leading to a safer and more efficient environment.
Monthly Engineering Safety Checks
This checklist is crucial for preventing accidents, ensuring structural integrity, and minimizing downtime, ultimately leading to a safer and more efficient environment.
Charge Battery Check diesel oil, top up if necessary Check lubrication oil level Run pump Check pressure on hydrant
Check Port or Stbd anchor wash valve is open. Start fire pump manually from laundry breaker panel. Check pressure Start pump remotely, port side locker Clean pump sea strainer
Bilge alarms are sounding in E/R, Crew mess and Bridge. Aft E/R bilge sensor Fwd E/R bilge sensor Cofferdam bilge sensor Port Midship bilge sensor Stbd Midship bilge sensor Bow-thruster bilge sensor Fore-peek bilge sensor
Description To Check Emergency lights press emergency lights el.contactor (Stbd Side under Bridge). Check Following Emergency lights: Bridge Port Side Entrance above door. Aft Guest Cabin LED strip bellow door. Water Tight door LED strip bellow door. MISSING to be investigated. Port Mid Guest Cabin LED strip bellow door. Stbd Mid. Guest Cabin LED strip bellow door. Port Fwd. Guest Cabin LED strip bellow door. Stbd Fwd. Guest Cabin LED strip bellow door. Steps to Lower Lobby third step only! To be investigated. Captain Cabin LED strip bellow door. Crew Cabin Port Side above door. Crew Cabin Port Side bathroom above door. Crew Cabin Mid above door. Crew Cabin Mid bathroom above door. Crew Cabin Stbd above door. Crew Cabin Stbd bathroom above door. Crew mess to E/R entrance. Control Room Center E/R Central walkway Fwd. E/R Central walkway Mid. E/R Centralwalkway Aft E/R Port Side Fwd E/R Port Side Mid E/R Port Side Aft E/R Stbd Side Fwd E/R Stbd Side Mid E/R Stbd Side Aft.
1. E/R aft Port Turbine Exhaust 2. E/R aft Stbd Turbine Exhaust 3. E/R aft of M/E Port 4. E/R aft of M/E Stbd 5. E/R top mid M/E Port 6. E/R top mid M/E Stbd 7. E/R top fwd M/E Port 8. E/R top fwd M/E Stbd
1. Remove seat Crew mess Port Aft corner and locate Fuel quick closing remote handles. 2. Activate Main engines quick closing valve by puling handle marked main engine quick closing valve. 3. Activate Generators quick closing valve by puling handle marked Generators quick closing valve. 4. Remove fridge and in the bilge under manually reset 2 valves 5. Visually check valve condition and grease if necessary
Source: MY Thunder C (Community Member)