Back

Daikin DSH Series 3-5 Tons DSH060-H - High Efficiency (5 Tons) Maintenance

Ensure the safety of your workers and the quality of work by using the Daikin DSH Series 3-5 Tons DSH060-H - High Efficiency (5 Tons) Maintenance. With quick and easy to follow steps and warnings.
MaintainX
04/26/2021

Daikin DSH Series 3-5 Tons DSH060-H - High Efficiency (5 Tons) Maintenance

Ensure the safety of your workers and the quality of work by using the Daikin DSH Series 3-5 Tons DSH060-H - High Efficiency (5 Tons) Maintenance. With quick and easy to follow steps and warnings.

    WARNING! HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

    WARNING! TO PREVENT PERSONAL INJURY OR DEATH DUE TO IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE, REFER TO THIS MANUAL. FOR ADDITIONAL ASSISTANCE OR INFORMATION, CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.

    CAUTION :SHEET METAL PARTS, SCREWS, CLIPS AND SIMILAR ITEMS INHERENTLY HAVE SHARP EDGES, AND IT IS NECESSARY THAT THE INSTALLER AND SERVICE PERSONNEL EXERCISE CAUTION.

    FILTERS

    CAUTION: TO PREVENT PROPERTY DAMAGE DUE TO FIRE AND LOSS OF EQUIPMENT EFFICIENCY OR EQUIPMENT DAMAGE DUE TO DUST AND LINT BUILD UP ON INTERNAL PARTS, NEVER OPERATE UNIT WITHOUT AN AIR FILTER INSTALLED IN THE RETURN AIR SYSTEM.

    CABINET FINISH MAINTENANCE

    CLEAN OUTSIDE COIL (QUALIFIED SERVICER ONLY)

    LUBRICATION

    FUNCTIONAL PARTS

    TROUBLESHOOTING

    THE FOLLOWING INFORMATION IS FOR USE BY QUALIFIED SERVICE AGENCY ONLY: OTHERS SHOULD NOT ATTEMPT TO SERVICE THIS EQUIPMENT.

    Common Causes of Unsatisfactory Operation of Heat Pump on the Heating Cycle.

    INADEQUATE AIR VOLUME THROUGH INDOOR COIL

    OUTSIDE AIR INTO RETURN DUCT

    UNDERCHARGE

    POOR “TERMINATING” SENSOR CONTACT

    MALFUNCTIONING REVERSING VALVE - THIS MAY BE DUE TO:

    Solenoid not energized

    No voltage at unit’s solenoid

    Valve will not shift:

    Undercharged

    Valve Body Damaged

    Unit Properly Charged

Source: Daikin

Please note that any procedure, checklist, or other document available in the MaintainX Global Procedure Library is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.