    Assembly Number:

    Serial Number:

    Field Assigned Serial Number: (if applicable)

    Equipment Description:

    Test Date:

    Pump and Recorder Information

    Pump Type:

    Recorder Type:

    Recorder Serial Number:

    Pressure Rating:

    Recorder set at: (inches per minute)

    Fill Fluid

    if the answer is "oneOf [Other]"

    Description if other:

    Notes:

    Function each manual valve fully open and fully closed checking for ease of operation and number of turns to function. (as per manufacturer's recommendation)

    • Pass
    • Flag
    • Fail

    Cycle and grease valves as needed

    • Pass
    • Flag
    • Fail

    Rig up pressure test unit to master valve lower test cap (from direction of flow)

    • Pass
    • Flag
    • Fail

    Test chart is required, use 30,000 psi pressure recorder, attach test charts to this report

    • Pass
    • Flag
    • Fail

    Pressure recorder to be with acceptable calibration date

    • Pass
    • Flag
    • Fail

    Acceptable leakage from pressure test is 0 psi

    • Pass
    • Flag
    • Fail

    Ensure all outlets are have test flanges installed with needle valves

    • Pass
    • Flag
    • Fail

    Open all FH-5 valves and needle valves

    • Pass
    • Flag
    • Fail

    Fill FH-5 with water from lower master valve test cap

    • Pass
    • Flag
    • Fail

    All pressure test will be conducted with a low at 1000 psi for 5 minutes and a high of 15,000 psi for 15 minutes.

    • Pass
    • Flag
    • Fail

    Test 1

    Master Valve Test -Close Master Valve

    Conduct Low Pressure Test (1000 PSI) - Test Pressure

    Conduct Low Pressure Test (1000 PSI) - Test Duration

    Conduct High Pressure Test (15,000 PSI) - Test Pressure

    Conduct High Pressure Test (15,000 PSI) - Test Duration

    After successful test bled down pressure to 0 psi through test pump assembly

    Test 2

    Crown Valve Test / Surface Safety Valves Test Open Master Valve, Close Crown Valve, Close Surface Safety Valves FAQ-SSV-100A & B

    Conduct Low Pressure Test (1000 PSI) - Test Pressure

    Conduct Low Pressure Test (1000 PSI) - Test Duration

    Conduct High Pressure Test (15,000 PSI) - Test Pressure

    Conduct High Pressure Test (15,000 PSI) - Test Duration

    After successful test bled down pressure to 0 psi through test pump assembly

    Completion

    Comments:

    Chart Recorder S/N:

    Chart Recorder Calibration Date:

    Test Completed by:

    Test Witnessed by:

Source: MaintainX (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.